Name
Group
Name
Group
No samples selected yet.
All Resin samples come as 2.5 ml pre-filled colums compatible with the AKTA system. You can request up to 40 samples at a time. The first Resin Sample is free, the quote for the other samples will be shared with you in the confirmation email.
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Resin parameters

Matrix
Highly cross-linked agarose
functional group
AR rProtein A
d50, µm
85
Dynamic Binding Capacity
≥60 mg human IgG/ml
Recommended Flow Rate
90–400 cm/h
Maximum Flow Rate
500 cm/h
Maximum Working Pressure
5 bar
maximum temperature
2–40°C
* Measurement conditions of dynamic binding capacity: packing height, 10 cm; retention time, 6 minutes; test buffer, 0.02M NaH2PO4 solution, 0.15M NaCl, pH 7.4, when IgG breakthrough reaches 10% of starting concentration.

Chemical resistance

pH Stability
3–12
Chemical Stability
Common aqueous solution used in protein A chromatography
* The physical and chemical properties and functions of the chromatographic resin have no obvious change after being placed in an environment of 40°C and pH 3–12 for 7 days.

Resin description

Lepta SuRe LX is an affinity chromatography resin for antibody purification, separating through the specific interaction between antigen and antibody. It is designed to handle high concentrations of monoclonal antibodies and combines high capacity, high flow rate and alkali resistance:

  • High flow rate and high dynamic binding capacity reduce processing time.
  • The modified alkali-resistant rProtein A ligand tolerates 0.5M NaOH for cleaning-in-place (CIP).

Method of use

Chromatographic conditions

Buffer selection. Equilibration, binding and washing buffer: 20 mM sodium phosphate, 150 mM NaCl, pH 7.2. Elution buffer: 0.1M sodium citrate, pH 3.0–3.6.

Flow rate. Select a linear flow rate of 90–400 cm/h according to the column bed height.

Sample pretreatment. Filter the sample through a 0.45 µm microporous membrane before loading to prevent the column from clogging. Adjust the pH and conductivity of the sample to be consistent with the equilibration buffer, using dilution, ultrafiltration or desalting.

Chromatography steps

  1. Equilibration. Use equilibration buffer to fully equilibrate the column until the pH and conductivity are stable and consistent with the equilibration buffer. This step usually requires 3–5 column bed volumes (CV).
  2. Sample loading. Determine the loading volume and loading amount from the binding capacity measured in a small-scale test.
  3. Washing. Use equilibration buffer or another suitable buffer to wash the column until the UV signal stabilises and returns to baseline.
  4. Elution. Elute at lower pH with the elution buffer.
  5. Re-equilibration. Re-equilibrate the column with equilibration buffer.

Cleaning and sterilisation

Contaminants such as lipids, endotoxins and proteins accumulate on the column as the number of uses increases. Determine the frequency of cleaning-in-place (CIP) according to the degree of contamination. Where contamination is considerable, CIP after each use is recommended to ensure repeatability of results and to prolong the working life of the resin.

Recommended cleaning conditions:

  • Pre-wash: rinse the column with 3 CV of equilibration buffer.
  • Alkali wash: flush the column with at least 2 CV of 0.5M NaOH for 10–15 minutes.
  • Final rinse: immediately flush the column with at least 5 CV of sterile equilibration buffer at pH 7–8.

To reduce microbial load, treat the resin with 0.5–1M NaOH solution for 15–30 minutes.

Storage

Keep unopened resin in the original container at 4–30°C in a well-ventilated, dry and clean place. Do not freeze. Wash the used column with 2–3 CV of 20% ethanol solution and store at 2–8°C.

Destruction and recycling

Chromatography resin is difficult to degrade in nature, so incineration of waste resin is recommended. For resin that has been in contact with biologically active samples such as viruses and blood, follow local biosafety requirements before destroying or disposing of it.

Packing method

Detailed information on resin packaging is available on request. Please contact your local distributor.

Ordering information

  • 651-00025 — 25 ml
  • 651-00100 — 100 ml
  • 651-00500 — 500 ml
  • 651-01000 — 1 L
  • 651-05000 — 5 L
  • 651-10000 — 10 L
  • 651-20000 — 20 L
Download Data Sheet

Here are some frequently asked questions

Better Energy Starts Here that is Powered by Advanced Solar Materials and with it’s Modern Tech

How long does it take to install solar panels?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.

What services do you offer for businesses?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.

Do you offer warranties on your products?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.

Can small businesses benefit from your services?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.

What kind of maintenance is required for solar systems?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.