Resin parameters

Matrix
Polystyrene-divinylbenzene (PS/DVB)
functional group
Sulfomethyl
Function
SCX
d50, µm
15
Dynamic Binding Capacity
≥80 mg lysozyme/ml
Recommended Flow Rate
150–900 cm/h
Maximum Flow Rate
1800 cm/h
Maximum Working Pressure
40 bar

Chemical resistance

pH Stability
2~13 (working range), 1~14 (CIP)
Temperature Resistance
Do not freeze. Tolerates 121°C high-pressure sterilisation
Chemical Stability
Stable in common aqueous buffers: 1.0 M NaOH+, 1.0 M HCl, 100% ethanol, 100% isopropyl alcohol, 100% acetonitrile, 100% methanol
* The physical and chemical properties and functions of the chromatographic resin have no obvious change after being placed in an environment of 40°C and pH 2–12 for 7 days.

Resin description

Helios 15S is an IEX resin based on highly cross-linked porous polystyrene-divinylbenzene (PS/DVB) monodisperse microspheres, with chemical compounds bonded to the microsphere surface to give a highly stable hydrophilic layer. It combines a high flow rate, high resolution, high capacity, high rigidity, good biocompatibility and physical and chemical stability. Compared with traditional chromatography resins it significantly improves the production efficiency and sample recovery of the downstream purification process, and is widely used in the capture, intermediate purification and fine purification of biomolecules such as antibodies, proteins, peptides and nucleic acids.

Method of use

Chromatographic conditions

Buffer selection. Select buffer salts whose buffer groups do not interact with the resin. Use a low-salt equilibration buffer (less than 5 mS/cm) at a pH about 1 unit below the isoelectric point of the target molecule to promote binding, and consider the stability of the sample in that buffer. Elution buffers are usually prepared by adding a high concentration of salt, such as 1M NaCl, or a high-pH buffer to the equilibration buffer.

Flow rate. Select a linear flow rate of 150–900 cm/h according to the column bed height; the greater the bed height, the lower the flow rate.

Sample pretreatment. Filter the sample through a 0.45 µm microporous membrane before loading to prevent the column from clogging. Adjust the pH and conductivity of the sample to match the equilibration buffer, using dilution, ultrafiltration or desalting with Persedex G-25.

Chromatography steps

  1. Equilibration. Wash the column with equilibration buffer until the pH and conductivity at the column outlet are essentially the same as the equilibration buffer. This usually requires 3–5 column bed volumes (CV).
  2. Sample loading. Determine the loading volume from the mass of the sample and the binding capacity of Helios 15S.
  3. Rinsing. Wash the column with equilibration buffer until the UV absorbance falls to an appropriate value.
  4. Elution. Use a linear or step gradient to increase the strength of the elution buffer, eluting substances of different binding strength from the column. Collect the fractions and identify those containing the target molecule.
  5. Regeneration. Flush the column with a high concentration of salt, such as 2M NaCl.
  6. Re-equilibration. After rinsing with equilibration buffer, the next sample can be loaded and the cycle repeated.

Cleaning and sterilisation

Contaminants such as lipids, endotoxins and proteins accumulate on the column as the number of uses increases. Determine the frequency of cleaning-in-place (CIP) according to the degree of contamination. Where contamination is considerable, CIP after each use is recommended to ensure repeatability of results and to prolong the working life of the resin.

Recommended cleaning conditions by contaminant type:

  • Strongly binding proteins: wash with 5 CV of 2M NaCl solution, or use a high-salt buffer at not lower than pH 2, such as 1M NaAc solution.
  • Strongly hydrophobic and precipitated proteins: wash with 5 CV of 1M NaOH solution, then wash out the alkali with 5–10 CV of ultrapure or pure water.
  • Lipoproteins and lipids: wash with 5 CV of 70% ethanol or 30% isopropanol, then rinse with 5–10 CV of ultrapure or pure water.

Degas 70% ethanol or 30% isopropanol before use. Use a flow rate of 30–60 cm/h during CIP. Use reverse cleaning where clogging is severe.

To reduce microbial load, treat the resin with 0.5–1M NaOH solution for 15–30 minutes. The resin can also be autoclaved at 121°C (pH 7) for 20 minutes.

Storage

Keep unopened resin in the original container at 4–30°C in a well-ventilated, dry and clean place. Do not freeze. Wash the used column with 2–3 CV of 20% ethanol solution containing 0.2M NaAc and store at 2–8°C.

Destruction and recycling

Chromatography resin is difficult to degrade in nature, so incineration of waste resin is recommended to protect the environment. For resin that has been in contact with biologically active samples such as viruses and blood, follow local biosafety requirements before destroying or disposing of it.

Packing method

Detailed information on resin packaging is available on request. Please contact your local distributor.

Ordering information

  • 112-00025 — 25 ml
  • 112-00100 — 100 ml
  • 112-00500 — 500 ml
  • 112-01000 — 1 L
  • 112-05000 — 5 L
  • 112-10000 — 10 L
  • 112-20000 — 20 L
Download Data Sheet

Here are some frequently asked questions

Better Energy Starts Here that is Powered by Advanced Solar Materials and with it’s Modern Tech

How long does it take to install solar panels?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.

What services do you offer for businesses?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.

Do you offer warranties on your products?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.

Can small businesses benefit from your services?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.

What kind of maintenance is required for solar systems?

We provide a wide range of green energy solutions, including solar panel installation, maintenance, and energy efficiency consultations tailored to your needs.